SR-915 WiFi gas sensor for CH4 detection with 2.4GHz WiFi, Tuya App notifications, AC100–240V input, a 6% LEL alarm setting, and an indoor-use design.

CONTACT US
Description
Order

The WiFi gas sensor SR-915 is an indoor combustible gas detector designed for CH4 monitoring. It combines local gas leak alarms with 2.4GHz WiFi communication and Tuya App notifications. Users can receive remote alerts and check device status through a connected smartphone.

The SR-915 supports AC100–240V input and has a specified alarm concentration of 6% LEL. It features an audible alarm, a compact ABS housing, and a plug-and-play installation design. The published warm-up time is approximately three minutes.

For distributors, wholesalers, smart-home suppliers, and project contractors, the SR-915 provides a connected option for indoor gas safety applications. SUMRING also supports OEM and ODM discussions for suitable product and packaging requirements.

SR-915 WiFi Gas Sensor Detector with Tuya App Alerts

What Are the Main Features of the SR-915 WiFi Gas Sensor?

1. 2.4GHz WiFi and Tuya App Notifications

The SR-915 WiFi gas sensor supports a 2.4GHz WiFi connection and works with the Tuya App. When the detector is connected and configured correctly, users can receive gas alarm notifications and check device status remotely.

Remote monitoring depends on the network connection, app configuration, and supported device functions. Buyers should confirm the setup process and app requirements before ordering for a project.

2. CH4 Combustible Gas Detection

The SR-915 is specified for combustible gas detection, particularly methane (CH4). Methane is a major component of natural gas, so the detector may be considered for suitable indoor natural gas monitoring applications.

Gas compatibility is important when selecting an alarm. Do not assume that a detector specified for CH4 is suitable for LPG, propane, or every other combustible gas.

3. Specified Alarm Concentration of 6% LEL

The published SR-915 specification lists an alarm concentration of 6% LEL and an error of ±3% LEL. LEL stands for Lower Explosive Limit.

These figures should be checked against the approved technical manual and the requirements of the destination market. Buyers should not treat the stated error as a substitute for an independently verified accuracy specification.

4. Local Audible Warning

The SR-915 provides a local audible alarm with a specified sound pressure of at least 70 dB at a distance of one meter.

A local warning helps alert people near the detector. WiFi and app notifications provide an additional communication channel, but remote alerts should not replace the required local alarm or appropriate emergency procedures.

5. AC100–240V Power Input

The SR-915 supports AC100–240V input. Its published average power consumption is no more than 3W.

This input range may support projects in different power markets, subject to the approved product configuration and local electrical requirements. Confirm the supplied plug type and installation method before placing a bulk order.

6. Simple Indoor Installation

The SR-915 uses a compact ABS housing and a plug-and-play design intended to simplify installation. Its published dimensions are 90 × 90 × 59 mm, excluding the plug from the measurement.

The specified operating temperature is -10°C to +55°C. The published working humidity is up to 95% RH, non-condensing. The product is listed for indoor use and should not be assumed suitable for outdoor or hazardous-area installation.

SR-915 WiFi Gas Sensor Technical Specifications

The table below summarizes the published SR-915 specifications. B2B buyers can use these values for initial product comparison and project planning. Confirm the latest approved datasheet before final technical approval.

Parameter Specification Parameter Specification
Model Number SR-915 Working Voltage AC100–240V
Network 2.4GHz WiFi Average Power Consumption ≤3W
Warm-up Time About 3 Minutes Detection Gas Combustible Gas (CH4)
Alarm Concentration 6% LEL Published Error ±3% LEL
Alarm Sound Pressure ≥70 dB at 1 Meter Working Temperature -10°C to +55°C (Indoor Use)
Working Humidity ≤95% RH, Non-condensing Product Size L90 × W90 × H59 mm (Plug Excluded from Measurement)

Technical Note: The values in this table reflect the published SR-915 product information. Verify the alarm setting, error definition, electrical configuration, and applicable approvals against the latest manufacturer documentation before project acceptance.

How Does the SR-915 WiFi Gas Sensor Work?

The SR-915 combines local gas detection with network communication. The sensing function monitors the target gas, while WiFi supports remote notifications and device status access through the Tuya App.

Step 1: Detect Combustible Gas

Gas in the surrounding air reaches the detector’s sensing element. The detector responds to the target gas specified for this model: CH4 (methane).

Step 2: Evaluate the Gas Signal

The detector processes the sensor signal and checks it against its configured alarm condition. The published SR-915 alarm concentration is 6% LEL, with a listed error of ±3% LEL.

Step 3: Activate the Local Alarm

When the configured alarm condition is reached, the detector activates its local audible warning. The specified alarm sound pressure is at least 70 dB at one meter.

Step 4: Send a Remote Notification

When the detector is connected to a suitable 2.4GHz WiFi network and configured in the Tuya App, supported alarm notifications and device status information can be accessed remotely.

The network connection and the local detection function serve different purposes. Remote notification depends on the network and app setup. Do not assume that remote alerts will be delivered during a network or service interruption.

For general setup information, consult the official Tuya guide to configuring a WiFi device. Follow the SR-915 user manual for the exact pairing procedure.

Where Can the SR-915 Be Used?

The SR-915 WiFi gas sensor is listed for indoor CH4 detection applications. Potential uses include suitable apartments, rental properties, smart homes, kitchens, and selected commercial indoor environments.

Before choosing the product, buyers should confirm the target gas, installation location, WiFi coverage, electrical supply, and local regulatory requirements. The detector should not be treated as an outdoor or hazardous-area device without the necessary approvals.

For a comparison of connected and conventional gas alarms, read our guide: SR-915 Smart WiFi Gas Detector vs Traditional Gas Alarm.
You can also review our guide to combustible gas leak detector selection.

FAQs

1. What gas does the SR-915 detect?

The SR-915 is specified for combustible gas detection, especially CH4 (methane). Buyers should confirm the target gas before ordering and should not assume that this model is suitable for LPG or propane.

2. Which WiFi frequency does the SR-915 support?

The published specification lists 2.4GHz WiFi. Confirm that the installation network supports this frequency before setting up the Tuya App.

3. Can I receive gas alarm notifications on my phone?

Yes. The SR-915 supports Tuya App notifications and remote monitoring when the device is connected and configured correctly. Network access and app setup are required for the connected functions.

4. What is the operating voltage of the SR-915?

The published operating voltage is AC100–240V. Buyers should confirm the supplied plug configuration and local electrical requirements for the destination market.

5. What is the alarm concentration?

The published alarm concentration is 6% LEL, and the listed error is ±3% LEL. Confirm the interpretation of these values in the approved datasheet and check the applicable requirements for your project.

6. How long is the warm-up time?

The published warm-up time is about three minutes. Follow the product manual for the correct startup and installation procedure.

7. Can the SR-915 be installed outdoors?

The current specification lists indoor use, with an operating temperature of -10°C to +55°C and working humidity up to 95% RH, non-condensing. Do not use it outdoors unless the manufacturer confirms that the installation is permitted.

8. Does SUMRING support OEM and ODM orders?

SUMRING supports OEM and ODM discussions for suitable orders. Buyers can discuss branding, packaging, documentation, order quantity, and target-market requirements with the sales team.

Request SR-915 WiFi Gas Sensor Details

SUMRING supplies gas detection products for distributors, wholesalers, smart-home suppliers, contractors, and private-label brands.

To evaluate the SR-915 for your project, provide the target market, required quantity, CH4 detection requirements, power configuration, WiFi setup, and applicable approval requirements.

Contact SUMRING to request the latest technical datasheet, sample information, pricing, and OEM or ODM options.

Order





    GET FREE QUOTE

    +86 136 7899 9834

    + 86 -755 89571207

    info@sumring.com

    Building D, No. 7 Songshan Road, Xinmu Community, Pinghu Subdistrict, Longgang District, Shenzhen