SR-918 Dual-Gas LCD Alarm with Voice and Valve Options Product Overview
SR-918 CO and combustible gas detector alarm detects CO and combustible gas with LCD display, voice alert, flash alarm, 85dB sound, AC90–240V power, and optional valve output.
A CO and Combustible Gas Detector Alarm monitors both carbon monoxide and combustible gas hazards in one device. It helps users identify gas-related warning conditions in suitable indoor environments.
The SUMRING SR-918 CO and Combustible Gas Detector Alarm combines an LCD display, voice alerts, flashing warnings, and an 85 dB audible alarm. With AC 90–240V power and optional electromagnetic valve control, the series supports different residential and commercial project requirements.
Why Choose the SR-918 Series?
For distributors and system integrators, selecting a CO and Combustible Gas Detector Alarm involves more than comparing alarm prices. The target gas, power supply, warning method, and external control interface must match the project requirements.
The SR-918DSY provides combined gas monitoring without valve output. The SR-918DVY adds an electromagnetic valve interface for compatible gas shut-off applications.
How Does the SR-918 Gas Alarm Work?
During normal operation, the CO and Combustible Gas Detector Alarm monitors the surrounding air through its detection system. After an approximately 180-second warm-up period, the device evaluates gas conditions against its specified alarm settings.
When an alarm condition is reached, voice and flashing warnings help alert occupants. The SR-918DVY can also activate a compatible electromagnetic valve through its designated output.
Key Features of the SR-918 Gas Alarm
- Dual-Gas Monitoring: Detects carbon monoxide and combustible gas hazards through one alarm unit.
- LCD Display: Provides a visible interface for checking gas-related information and alarm status.
- Voice and Flash Alerts: Combines spoken warnings, flashing indicators, and an 85 dB audible alarm.
- Time-Based CO Warning: Uses specified alarm response times at different carbon monoxide concentrations.
- Optional Valve Linkage: The SR-918DVY supports a compatible electromagnetic valve for gas shut-off control.
- Wide AC Power Input: Supports AC 90–240V for different regional electrical requirements.
- Automatic Fault Detection: Monitors sensor operating status and helps identify potential faults.
- Project-Friendly Design: ABS housing and SMT construction support residential and commercial gas alarm applications.
SR-918 Technical Specifications
| Parameter | SR-918DSY | SR-918DVY | Technical Notes |
|---|---|---|---|
| Brand | SUMRING | SUMRING | Manufacturer brand |
| Gas Detection | Combustible Gas + CO | Combustible Gas + CO | Dual-gas alarm |
| Power Supply | AC 90–240V | AC 90–240V | AC-powered versions |
| Optional Battery | 9V Rechargeable | 9V Rechargeable | Configuration dependent |
| LCD Display | Yes | Yes | Visible gas information |
| Alarm Type | Voice + Flash | Voice + Flash | Audible and visual warning |
| Sound Level | 85 dB at 1 m | 85 dB at 1 m | Published sound specification |
| Solenoid Valve Output | No | Yes | Compatible valve required |
| Combustible Gas Alarm | 7 ± 3% LEL | 7 ± 3% LEL | Published threshold |
| Gas Alarm Reference | 3500 ± 1000 ppm | 3500 ± 1000 ppm | Confirm calibration gas |
| CO at 30 ppm | After 2 hours | After 2 hours | Published response condition |
| CO at 50 ppm | Within 60–90 min | Within 60–90 min | Published response condition |
| CO at 100 ppm | Within 10–40 min | Within 10–40 min | Published response condition |
| CO at 300 ppm | Within 3 min | Within 3 min | Published response condition |
| Warm-Up Time | About 180 seconds | About 180 seconds | After power-up |
| Operating Temperature | 0°C to +50°C | 0°C to +50°C | Indoor operating range |
| Ambient Humidity | 10%–95% RH | 10%–95% RH | Confirm site conditions |
| Housing Material | ABS Plastic | ABS Plastic | Detector enclosure |
| Dimensions | 155 × 110 × 45 mm | 155 × 110 × 45 mm | L × W × H |
| Sensor Fault Detection | Yes | Yes | Automatic fault monitoring |
Technical Note: Values are based on published SUMRING product specifications. CO response times are product test conditions, not safe exposure periods. Battery operation, target-gas calibration, valve compatibility, and required certificates must be verified for the exact configuration.

How Does the SR-918 CO and Gas Alarm Work?
The SR-918 monitors the surrounding air for carbon monoxide and combustible gas. Its detection system evaluates gas conditions and activates warnings when the specified alarm requirements are met.
Step 1: Power and Warm-Up
Connect the detector using its specified AC power supply. After power-up, the unit requires approximately 180 seconds to complete its warm-up period.
Step 2: Monitor Two Gas Hazards
The device monitors carbon monoxide and combustible gas. The required gas type and sensor calibration should match the intended application.
Step 3: Evaluate Alarm Conditions
The combustible gas alarm has a published setting of 7 ± 3% LEL. LEL means Lower Explosive Limit.
Carbon monoxide warning behavior depends on both concentration and time. The SR-918 provides specified response conditions at 30, 50, 100, and 300 ppm.
Step 4: Activate Warning Signals
When an alarm condition is reached, the detector activates its voice and flashing warnings. The audible alarm has a published sound level of 85 dB at one meter.
The LCD provides a visual interface to support alarm identification.
Step 5: Support Gas Valve Control
The SR-918DVY can send an output signal to a compatible electromagnetic valve.
This allows a properly configured gas safety installation to initiate gas shut-off during a relevant alarm event. The SR-918DSY does not include this output function.
Valve matching, wiring, installation, and system verification must follow the approved technical documentation.
Where Is a CO and Combustible Gas Detector Alarm Used?
The SR-918 series can be considered for homes, apartments, hotels, kitchens, and suitable commercial gas safety projects.
Installation requirements depend on the target gas, sensor configuration, building conditions, and applicable local regulations. Buyers should confirm the intended application before ordering.
FAQs
1. Can the SR-918 detect both carbon monoxide and natural gas?
Yes. The SR-918 series is designed to monitor carbon monoxide and combustible gas. Natural gas is one of the applications described by SUMRING. Buyers should confirm that the supplied sensor configuration is calibrated for the required target gas.
2. Can the SR-918 detect LPG as well as CO?
SUMRING lists LPG among the intended combustible gas applications. However, LPG and natural gas have different characteristics. Buyers should confirm the target-gas calibration and approved installation instructions before ordering.
3. What is the difference between SR-918DSY and SR-918DVY?
Both models monitor CO and combustible gas. They include LCD displays, voice warnings, and AC 90–240V power. The SR-918DVY adds electromagnetic valve output. The SR-918DSY does not support that output.
4.What Should Buyers Check Before Ordering a CO and Combustible Gas Detector Alarm?
Buyers should verify the target gas, sensor calibration, operating voltage, valve output requirements, and applicable certification documents. For project procurement, sample evaluation and installation documentation are also important.
5. Is the SR-918 suitable for wholesale, OEM, and ODM projects?
SUMRING welcomes wholesale and OEM/ODM discussions for gas safety products. Buyers can request technical documents, sample evaluation, branding options, and project-specific quotations. Required certifications and customization feasibility should be confirmed before placing an order.
Gas Safety Reference
Carbon monoxide is an odorless and colorless gas. Proper detection, appliance maintenance, and safe ventilation are important parts of gas safety planning.
For additional safety information, refer to the CDC Carbon Monoxide Poisoning Basics.
Wholesale and OEM/ODM Gas Safety Solutions?
SUMRING supplies gas detection products for distributors, wholesalers, contractors, and system integrators.
The SR-918 series offers two practical selection options: the SR-918DSY for combined CO and combustible gas warning, and the SR-918DVY for projects that also require compatible electromagnetic valve control.
For a broader model comparison, read the SR-918 Series Selection Guide.
You can also explore the SUMRING Gas Detector Collection for additional product configurations.
Looking for SR-918 CO and Combustible Gas Detector Alarm wholesale pricing or OEM/ODM support? Contact SUMRING with your target country, required gas type, order quantity, power requirements, and valve-control needs. We can help you review the suitable product configuration.