Welcome to Shenzhen Sumring Technology Co., Ltd.

PRODUCTS

SR-918DVY-C Relay Output Multi CO And Combustible LPG GasDetector LCD display

SR-918DVY-C is a DC12–24V combustible gas and CO leakage detector with LCD, voice alarm, relay output, sound & flash alert, sensor fault detection and solenoid valve linkage.

CONTACT US
Description
Order

SR-918DVY-C 12–24V Dual-Gas LCD Alarm with Relay Control

A Gas and CO Leakage Detector is a safety device that monitors combustible gas and carbon monoxide in one unit. It provides warning signals when either detection function identifies an alarm condition.

The SUMRING SR-918DVY-C Gas and CO Leakage Detector combines LCD display, voice warning, sound and flash alerts, relay output, and electromagnetic valve linkage.

Powered by DC 12–24V, this detector is designed for compatible low-voltage gas safety systems. It also features automatic sensor fault detection, an ABS housing, and an approximately 180-second warm-up period.

The SR-918DVY-C is suitable for evaluation in residential, commercial, and building gas safety projects where dual-gas monitoring and external alarm integration are required.

For distributors, contractors, and OEM/ODM customers, it offers multiple warning and control functions in one product.

Key Features of the SR-918DVY-C

  • Dual-Gas Detection: Monitors combustible gas and carbon monoxide in one device.
  • DC 12–24V Power: Supports compatible low-voltage gas safety installations.
  • LCD Display: Provides a visual interface for gas concentration and alarm information.
  • Voice Alarm: Uses spoken warnings to help identify alarm conditions.
  • 85 dB Sound and Flash Alarm: Combines an audible warning with flashing indication.
  • Relay Output: Provides an external alarm interface for compatible control equipment.
  • Electromagnetic Valve Linkage: Supports integration with a suitable gas shut-off valve.
  • Automatic Sensor Fault Detection: Identifies sensor fault conditions that may require maintenance.
  • SMT Electronic Design: Uses surface-mount electronic assembly.
  • ABS Housing: Provides a compact enclosure measuring 155 × 110 × 45 mm.

Why Choose This Gas and CO Leakage Detector?

The SR-918DVY-C is designed for projects that need more than a basic gas alarm.

Its combined gas detection functions monitor both combustible gas and carbon monoxide. The LCD and voice warning system provide visible and audible alarm information.

Relay output is another important feature for engineering applications. It allows the detector to send an alarm signal to compatible external equipment.

The electromagnetic valve interface also supports a gas shut-off arrangement when correctly configured.

For project buyers, the main advantage is the combination of DC 12–24V operation, dual-gas monitoring, and external linkage options.

SR-918DVY-C Technical Specifications

Parameter SR-918DVY-C Specification Function / Description Buyer Notes
Brand SUMRING Manufacturer OEM/ODM inquiries
Model Number SR-918DVY-C Dual-gas alarm Confirm order model
Detection Gas Combustible Gas + CO Dual-gas monitoring Confirm target gas
Power Supply DC 12–24V Low-voltage input Not AC 90–240V
LCD Display Yes Visual information Display configuration
Voice Alarm Yes Spoken warning Confirm language version
Alarm Output Relay + Sound + Flash Local and external warnings Check output specification
Relay Output Supported External signaling Confirm contact ratings
Electromagnetic Valve Supported Gas shut-off linkage Confirm valve compatibility
Combustible Gas Alarm 7 ±3% LEL Published alarm setting Confirm calibration gas
Gas Concentration Reference 3500 ±1000 ppm Additional published value Gas-dependent interpretation
CO at 30 ppm After 2 hours Published response condition Verify test method
CO at 50 ppm Within 60–90 min Published response condition Verify test method
CO at 100 ppm Within 10–40 min Published response condition Verify test method
CO at 300 ppm Within 3 min Published response condition Verify test method
Warm-Up Time Approximately 180 s Startup period Allow before monitoring
Sound Level 85 dB at 1 m Audible warning Published specification
Sensor Fault Detection Supported Automatic fault monitoring Maintenance function
Housing Material ABS Plastic Product enclosure Indoor applications
Operating Temperature 0°C to +50°C Working environment Published range
Ambient Humidity 10%–95% RH Working humidity Confirm site conditions
Dimensions 155 × 110 × 45 mm Product dimensions Check mounting space
Certification Verify by market Model-specific documentation Request valid reports
OEM/ODM Support By agreement Branding and project supply Confirm feasibility

Technical Note: Specifications follow the published SUMRING product information. The 7 ±3% LEL and 3500 ±1000 ppm values should be verified against the target calibration gas. CO response times are published alarm test conditions, not safe exposure periods. Relay ratings, valve compatibility, and required certifications must be confirmed before installation.

SR-918DVY-C Gas and CO Leakage Detector

How Does the SR-918DVY-C Gas and CO Leakage Detector Work?

The SR-918DVY-C monitors combustible gas and carbon monoxide and provides warning outputs when specified alarm conditions are detected.

Step 1: Power and Warm-Up

The detector operates on DC 12–24V power.

After startup, it requires approximately 180 seconds for warm-up before normal monitoring.

Step 2: Dual-Gas Monitoring

The detector monitors combustible gas and carbon monoxide through its detection system.

Its published combustible gas alarm setting is 7 ±3% LEL. Carbon monoxide warning behavior depends on the specified gas concentration and response time.

Step 3: LCD, Voice and Sound Alerts

When an alarm condition occurs, the detector activates voice, sound, and flashing warning functions.

The LCD provides a visual interface for reviewing gas-related information.

Step 4: Relay and Valve Linkage

The Gas and CO Leakage Detector supports relay output and electromagnetic valve linkage.

In a compatible installation, these interfaces allow an alarm condition to initiate external safety responses.

The output configuration, electrical ratings, and associated equipment must be checked against the approved wiring documentation.

Step 5: Fault Monitoring

The detector automatically checks for sensor fault conditions.

If a fault is detected, users should follow the product instructions for inspection and maintenance.

Where Can the SR-918DVY-C Be Used?

The SR-918DVY-C can be considered for suitable indoor gas safety projects, including:

  • Residential apartments with gas appliances
  • Hotel and commercial kitchen projects
  • Building utility rooms
  • Suitable boiler and fuel-burning equipment areas
  • Low-voltage building gas monitoring systems
  • Projects requiring compatible gas valve or external alarm linkage

Application suitability depends on target-gas calibration, installation conditions, local regulations, and required product approvals.

The detector should not be treated as explosion-proof equipment without specific supporting certification.

What Should Project Buyers Check Before Ordering?

When purchasing a Gas and CO Leakage Detector, buyers should verify five important points.

1. Detection Requirements: Confirm combustible gas type, CO detection requirements, and alarm response specifications.

2. Power Supply: Ensure the project provides compatible DC 12–24V power.

3. Relay Compatibility: Check output type, contact ratings, and connection requirements.

4. Valve Control: Confirm electromagnetic valve compatibility and the intended control arrangement.

5. Documentation: Request the datasheet, approved wiring diagram, certification documents, samples, and OEM/ODM quotation.

For a single-gas alternative, explore the SUMRING SR-918-NC Combustible Gas Detector.

For a broader comparison, read the SUMRING SR-918 Series Gas Detector Selection Guide.

FAQs

1. What gases does the SR-918DVY-C Gas and CO Leakage Detector detect?

The SR-918DVY-C detects combustible gas and carbon monoxide. It combines both detection functions in one unit. Buyers should confirm the combustible gas calibration and applicable CO response specifications before ordering.

2. What is the difference between SR-918DVY-C and SR-918-NC?

Both models operate on DC 12–24V and support relay output and electromagnetic valve linkage. The SR-918DVY-C also detects carbon monoxide and includes LCD and voice warning functions. The SR-918-NC is designed for combustible gas detection without those additional features.

3. Can the SR-918DVY-C connect to a gas valve or fire alarm control system?

The detector supports relay output and electromagnetic valve linkage. Connection to a fire alarm panel or another control device depends on electrical compatibility, relay specifications, and approved system design. Buyers should request the current wiring and interface documentation.

4. What are the combustible gas and CO alarm settings?

The published combustible gas setting is 7 ±3% LEL. The CO response specifications include 60–90 minutes at 50 ppm, 10–40 minutes at 100 ppm, and within three minutes at 300 ppm. At 30 ppm, the listing states an alarm after two hours. These figures must be verified for the applicable test standard.

5. Does SUMRING offer SR-918DVY-C wholesale and OEM/ODM services?

SUMRING supports wholesale purchasing and OEM/ODM discussions for gas detection products. Buyers can request product samples, available branding options, technical documents, and project quotations. Customization, MOQ, delivery terms, and required certifications should be confirmed before ordering.

Gas Safety Reference

Carbon monoxide is a colorless and odorless gas associated with incomplete fuel combustion. Suitable gas detection, proper installation, and regular appliance maintenance are important parts of a safety plan.

For independent information, refer to the CDC Carbon Monoxide Poisoning Basics.

This reference provides general safety guidance and does not certify or endorse the SR-918DVY-C.

Request an SR-918DVY-C Wholesale Quote

SUMRING supplies gas detection products for distributors, wholesalers, project contractors, system integrators, and OEM/ODM customers.

The SR-918DVY-C Gas and CO Leakage Detector combines dual-gas detection, DC 12–24V power, LCD display, voice warning, relay output, and electromagnetic valve linkage.

Contact SUMRING with your target country, gas type, order quantity, power requirements, and external linkage needs to discuss samples, technical documentation, and pricing.

Order





    GET FREE QUOTE

    +86 136 7899 9834

    + 86 -755 89571207

    info@sumring.com

    Building D, No. 7 Songshan Road, Xinmu Community, Pinghu Subdistrict, Longgang District, Shenzhen