SR-821THS 2 in 1 Detector Wholesale Combo smoke and carbon monoxide detector alarm

Battery Smoke and CO Alarm SR-821THS combines smoke and carbon monoxide detection with MCU processing, 85dB sound & flash alert, test/hush button, auto reset, and low battery warning.

CONTACT US
Description
Order

SR-821THS Battery Combo Alarm with Test/Hush and 85 dB Alert

A smoke and carbon monoxide detector is a dual-function safety device designed to detect smoke and carbon monoxide in one unit. It provides warning signals when either detection system identifies an alarm condition.

The SUMRING SR-821THS smoke and carbon monoxide detector combines dual-hazard monitoring, MCU signal processing, audible and flashing warnings, and convenient battery operation.

Powered by two 1.5V AA alkaline batteries, the SR-821THS operates at DC 3V. Its published audible alarm output is 85 dB at three meters.

The detector also includes a test/hush button, low-battery warning, automatic reset, and smoke chamber fault detection.

Designed for suitable indoor applications, the SR-821THS is an option for residential safety projects, distributors, wholesalers, and OEM/ODM buyers.

Key Features of the SR-821THS

  • Dual-Hazard Detection: Monitors smoke and carbon monoxide in one alarm unit.
  • MCU Signal Processing: Uses microcontroller-based processing to manage detection and alarm functions.
  • 85 dB Audible Warning: Provides a published sound output of 85 dB at three meters, together with flashing alarm indication.
  • Low-Power Battery Design: Operates on two 1.5V AA alkaline batteries with a static current of ≤10 μA.
  • Top Battery Compartment: Provides access for battery replacement without complex wiring.
  • Test/Hush Button: Supports routine alarm checking and temporary silence when permitted by the user manual.
  • Automatic Fault Monitoring: Checks for smoke chamber malfunction and provides low-battery warnings.
  • Auto Reset: Supports automatic return to normal operation when the specified reset conditions are met.
  • Tamper-Resistant Design: Includes battery-related tamper-resistant features and a shock-resistant housing design.
  • Flexible Mounting: Supports wall or ceiling mounting according to the approved installation instructions.

Why Choose the SR-821THS Combination Alarm?

Choosing a smoke and carbon monoxide detector can simplify product selection when a building requires both smoke and CO monitoring.

Instead of managing separate alarm types at every suitable location, contractors can evaluate one combination unit.

The SR-821THS focuses on practical maintenance features. Its top-access battery compartment supports battery replacement, while its test/hush button allows routine functional checks.

Low-battery warnings and automatic smoke chamber fault detection also help users identify conditions that require attention.

For project buyers, these features are useful when reviewing residential installations, property maintenance requirements, and wholesale product options.

SR-821THS Technical Specifications

Parameter SR-821THS Specification Function / Description Buyer Notes
Brand SUMRING Manufacturer brand OEM/ODM inquiries
Model Number SR-821THS Combination alarm Confirm order model
Detection Type Smoke + Carbon Monoxide Dual-hazard detection Not an LPG or methane detector
Signal Processing MCU Microcontroller-based operation Published feature
Operating Voltage DC 3V Battery power No fixed mains supply
Battery Type 2 × 1.5V AA Alkaline Replaceable batteries Check battery inclusion
Static Current ≤10 μA Low-power operation Published value
Alarm Current ≤25 mA Current during alarm Published value
Alarm Output Sound + Flash Audible and visual alerts Local warning
Alarm Sound Level 85 dB at 3 m Audible warning level Published measurement
Smoke Sensitivity 0.16 ±0.05 dB/m Smoke detection specification Confirm test standard
CO Sensitivity 150 ±50 ppm Published sensitivity figure Confirm response conditions
Test/Hush Button Supported Testing and temporary silence Follow user manual
Auto Reset Supported Automatic reset function Condition dependent
Low-Battery Warning Supported Battery maintenance alert Replace weak batteries
Chamber Fault Check Supported Smoke chamber self-check Maintenance feature
Battery Compartment Top Access Battery replacement Check enclosure configuration
Installation Wall / Ceiling Mounting options Follow approved positions
Operating Temperature -10°C to +50°C Working environment Published range
Working Humidity ≤95% RH Non-condensing conditions Avoid condensation
Product Dimensions 110 × 45 mm Published housing size Verify dimensional drawing
Battery Operating Period Over 3 years stated Low-power design claim Verify test conditions
Certification Market-dependent Model-specific compliance Request valid documents

Technical Notice: These values follow the current SR-821THS product listing. The published 150 ±50 ppm figure does not explain CO alarm timing or the applicable test method. Buyers should request the latest datasheet, alarm response information, dimensional drawing, and certification documents before project approval.

SR-821THS smoke and carbon monoxide detector

How Does the SR-821THS Smoke and Carbon Monoxide Detector Work?

The SR-821THS monitors two different hazards through its smoke and carbon monoxide detection functions.

Step 1: Battery Power and Startup

The detector operates using two 1.5V AA alkaline batteries.

Once correctly powered, its control electronics manage detection, alarm indication, and maintenance functions.

The low-power design helps reduce normal operating current. Actual battery life depends on battery quality, environmental conditions, and usage.

Step 2: Smoke Detection

The detector monitors its smoke sensing chamber for conditions that indicate a possible fire-related hazard.

When the smoke detection system reaches the specified alarm condition, the unit activates audible and flashing warnings.

The published smoke sensitivity is 0.16 ±0.05 dB/m.

Step 3: Carbon Monoxide Monitoring

The CO detection function monitors carbon monoxide, a colorless and odorless gas associated with incomplete fuel combustion.

When the specified CO alarm requirements are met, the unit activates its warning system.

CO alarm thresholds and response timing should be verified against the approved technical documentation.

Step 4: Audible and Visual Warning

The smoke and carbon monoxide detector provides an 85 dB alarm at three meters, together with flashing indication.

The warning signals help occupants recognize that an alarm condition requires attention.

In a real smoke or CO emergency, occupants should follow the building’s emergency procedures and move to safety.

Step 5: Testing, Silence, and Maintenance

The test/hush button supports routine alarm testing and appropriate temporary silencing.

The detector also includes low-battery warnings, automatic reset, and smoke chamber malfunction monitoring.

A hush function must not be used to ignore a suspected real emergency. Always follow the approved manual.

Where Can the SR-821THS Be Used?

The SR-821THS smoke and carbon monoxide detector can be considered for suitable residential and light commercial safety projects.

Typical applications for evaluation include:

  • Homes and residential apartments
  • Rental properties and residential renovations
  • Hotels and serviced accommodation
  • Student housing and dormitories
  • Suitable office areas and indoor building projects

The product page also describes shock resistance for vehicle-related use. However, vehicle installation must be separately verified against the required product approvals and installation standards.

For every application, buyers should confirm local smoke alarm and CO alarm regulations, mounting positions, and certification requirements.

What Should Wholesale Buyers Check?

For distributors and project contractors, selecting a smoke and carbon monoxide detector requires attention to product configuration, maintenance, compliance, and supply conditions.

Important purchasing checks include battery type, alarm output, CO response timing, mounting method, certification documents, and project quantity.

Buyers requiring a digital CO display can also review the SUMRING SR-824THS LCD Smoke and CO Alarm.

For broader technical background, read the SUMRING Battery Operated Smoke Carbon Monoxide Detector Guide.

FAQs

1. Does the SR-821THS smoke and carbon monoxide detector detect both hazards?

Yes. The SR-821THS combines smoke and carbon monoxide detection in one unit. It provides audible and flashing alarms when the relevant alarm conditions are met. It is not designed to replace a separate combustible gas detector for LPG or natural gas leaks.

2. What batteries does the SR-821THS use, and how long do they last?

The current product specification lists DC 3V operation using two 1.5V AA alkaline batteries. SUMRING states battery operation of over three years, but the exact runtime depends on battery type and operating conditions. Buyers should verify the approved battery specification and replacement requirements.

3. What do the test/hush button and low-battery warning do?

The test function supports routine checks of the alarm electronics and warning outputs. The hush function allows temporary silencing under the conditions described in the user manual. The low-battery warning alerts users when battery maintenance is needed.

4. Can the SR-821THS be installed on a wall or ceiling?

Yes. SUMRING lists both wall and ceiling mounting. However, the correct position depends on the approved product instructions, local fire safety regulations, and the building layout. Contractors should confirm that the mounting location is suitable for both smoke and CO monitoring.

5. Can SUMRING provide the SR-821THS for wholesale and OEM/ODM orders?

Yes. SUMRING supports wholesale and OEM/ODM discussions for qualified orders. Options may include logo printing, packaging, labeling, and instruction manual customization. Buyers should confirm MOQ, target-market certification, sample availability, and production lead time before ordering.

Fire Safety and Carbon Monoxide References

For independent fire safety information, read the U.S. Fire Administration Smoke Alarm Guidance.

For carbon monoxide information, see the CDC Carbon Monoxide Poisoning Basics.

These resources provide general safety guidance. They do not certify or endorse the SR-821THS.

Request SR-821THS Wholesale and OEM/ODM Pricing

SUMRING supplies smoke alarms, gas detectors, and related fire safety products for distributors, wholesalers, importers, and engineering contractors.

The SR-821THS smoke and carbon monoxide detector offers dual-hazard monitoring, replaceable battery power, an 85 dB audible warning, and practical testing and maintenance functions.

Contact SUMRING with your destination market, estimated order quantity, required certifications, packaging needs, and OEM/ODM requirements to discuss technical documentation, samples, and quotations.

Order