KH168 5 in 1 CO and Gas Detector with 9V Backup
KH168 5 in 1 CO and gas detector with CO and combustible gas monitoring, temperature and humidity display, audible and visual alarms, AC 110–220V power, and 9V battery backup.
A 5 in 1 CO and gas detector combines carbon monoxide detection, combustible gas monitoring, temperature display, humidity display, and audible and visual alarms in one device.
The SUMRING KH168 offers these functions with a clear digital display. It monitors CO and combustible gas levels while showing temperature and humidity readings. Users can view key information on one screen and receive local warnings when an alarm condition occurs.
The KH168 uses AC 110–220V power and supports a 9V alkaline backup battery. It also features adjustable screen brightness, alarm volume controls, and a self-test button.
For distributors, wholesalers, contractors, and private-label brands, this multi-function detector offers a compact option for suitable indoor gas safety projects. SUMRING supports OEM and ODM inquiries based on customer requirements.

What Are the Main Features of This 5 in 1 CO and Gas Detector?
1. Five Functions in One Device
The KH168 combines CO detection, combustible gas monitoring, temperature display, humidity display, and audible and visual alarm functions.
This design helps users check several environmental readings through one unit. The 5 in 1 CO and gas detector does not claim to detect five different gases.
2. Carbon Monoxide Detection
The KH168 has a published CO detection range of 0–2000 ppm and a CO alarm concentration of 150 ppm.
CO is a harmful gas that cannot be identified by smell alone. The detector provides local warnings according to its specified alarm settings.
Buyers should verify the alarm response, sensor specifications, and relevant safety standards for their destination market.
3. Combustible Gas Detection
The detector monitors combustible gas concentration within a published range of 0–10% LEL. Its specified gas alarm concentration is 5% LEL.
LEL means Lower Explosive Limit. The target combustible gas and calibration conditions must be confirmed before installation.
Do not assume that every combustible gas detector is suitable for all gas types.
4. Digital Temperature and Humidity Display
The digital screen provides temperature and humidity readings alongside gas monitoring information.
The published temperature display range is 1–176°F, with a stated tolerance of ±4°F. The humidity display range is 0–99%, with a stated tolerance of ±5%.
These functions provide additional environmental information. They should not be treated as certified temperature or humidity alarm functions.
5. AC Power with 9V Battery Backup
The 5 in 1 CO and gas detector operates from an AC 110–220V supply and supports a 9V alkaline backup battery.
The backup battery can help maintain operation during a temporary mains power interruption, provided the battery is installed and has sufficient capacity.
The backup operating duration is not specified on the current product page.
6. Adjustable Display and Alarm Volume
The KH168 includes BRIGHTNESS and VOLUME controls. Users can adjust the screen intensity and alarm volume according to the available product settings.
The correct alarm sound setting must meet applicable project and safety requirements.
7. Self-Test and Visual Indicators
A dedicated self-test button supports routine functional checks. Green, yellow, and red indicators help users identify operating and warning states.
The published alarm description includes a flashing red indicator. Follow the product manual to understand the complete indicator sequence.
KH168 5 in 1 CO and Gas Detector Technical Specifications
The following table lists the published KH168 specifications. It covers power supply, detection ranges, alarm thresholds, display functions, and environmental limits. Confirm the latest approved datasheet before project purchasing.
| Parameter | Specification | Parameter | Specification |
|---|---|---|---|
| Model Number | KH168 | Product Type | 5 in 1 CO and Gas Detector |
| Supply Voltage | AC 110–220V | Backup Battery | 9V Alkaline Battery |
| Static Power Consumption | ≤2W | Alarm Power Consumption | ≤3W |
| CO Alarm Concentration | 150 ppm | CO Detection Range | 0–2000 ppm |
| Minimum CO Display | >0 ppm (Published Value) | Gas Detection Range | 0–10% LEL |
| Gas Alarm Concentration | 5% LEL | Preheating Countdown | 180 Seconds |
| Operating Temperature | -10°C to +55°C | Operating Humidity | ≤95% RH |
| Storage Temperature | -25°C to +55°C | Storage Humidity | ≤95% RH |
| Temperature Display Range | 1–176°F (±4°F) | Humidity Display Range | 0–99% (±5%) |
| Product Dimensions | 124.3 × 56.5 × 57.7 mm | Work Indicator | Green Indicator On |
| Alarm Indication | Red Indicator Flashes During Alarm | Self-Test Function | Button Test and LED Indicators |
| Monitoring Functions | CO, Combustible Gas, Temperature, Humidity | Alarm Function | Audible and Visual Alarm |
| User Controls | Brightness and Volume | Gas Compatibility | Confirm Target Gas and Calibration |
Technical Note: Values are based on the current published KH168 specifications. Confirm sensor type, target gas, alarm response, applicable certifications, and backup battery performance before approving a safety project.
How Does the KH168 5 in 1 CO and Gas Detector Work?
The KH168 monitors carbon monoxide and combustible gas through its sensing system. It also measures and displays temperature and humidity. The device processes the readings and activates its local alarm when the specified gas alarm condition is met.
Step 1: Power On and Preheat
Connect the detector according to its approved power instructions. The published preheating countdown is 180 seconds. Follow the manual before relying on normal monitoring.
Step 2: Monitor CO and Combustible Gas
The detection system monitors the surrounding air for the supported gases. The published CO range is 0–2000 ppm, while the combustible gas range is 0–10% LEL.
Step 3: Display Environmental Readings
The digital display provides CO, combustible gas, temperature, and humidity information. This helps users review the reported conditions in one location.
Step 4: Activate the Gas Alarm
The published alarm settings are 150 ppm for CO and 5% LEL for combustible gas. When an alarm condition is reached, the detector provides audible and visual warnings.
Treat an alarm as a possible emergency. Move to a safe location and contact the appropriate emergency service. Do not ignore or disable an unexplained alarm.
Step 5: Support Backup Power
The 9V alkaline backup battery can support operation during a temporary AC power interruption. The actual backup duration depends on the battery condition and the approved configuration.
Step 6: Perform Routine Checks
The self-test button helps users check the supported warning functions. Regular inspection, cleaning, and battery maintenance should follow the manufacturer’s instructions.
What Should B2B Buyers Check Before Ordering?
The KH168 5 in 1 CO and gas detector may be considered for suitable indoor projects that require CO and combustible gas monitoring with a digital display.
Buyers should confirm the target combustible gas, alarm response, electrical supply, installation environment, and applicable local safety standards.
For project selection guidance, read How to Choose a Carbon Monoxide Detector for B2B Projects.
You can also explore SUMRING’s multi-gas detector product range to compare available models.
FAQs
1. What are the five functions of the KH168?
The KH168 combines CO detection, combustible gas monitoring, temperature display, humidity display, and audible and visual alarms.
2. Does the KH168 detect natural gas and LPG?
It detects combustible gas, but the exact gas types and calibration must be confirmed with SUMRING before ordering.
3. What is the CO alarm concentration?
The published CO alarm concentration is 150 ppm. Confirm the alarm response and applicable safety standard for your market.
4. What is the combustible gas alarm level?
The published gas alarm setting is 5% LEL, with a detection range of 0–10% LEL.
5. Does the KH168 work during a power outage?
It supports a 9V alkaline backup battery. Backup operation depends on battery condition and the product configuration.
6. Does the detector display temperature and humidity?
Yes. The digital screen shows temperature and humidity alongside the supported gas monitoring information.
7. Can users adjust the alarm volume?
Yes. The KH168 has brightness and volume controls. Settings must meet local alarm requirements.
8. Can SUMRING supply OEM or ODM orders?
Yes. SUMRING can discuss branding, packaging, manuals, quantities, and project-specific requirements.
Request a KH168 CO and Gas Detector Quotation
SUMRING supplies gas detection products for distributors, wholesalers, importers, contractors, and private-label customers.
For a quotation, please provide your destination country, required quantity, target gas, power plug requirements, certifications, and OEM or ODM needs.
Contact SUMRING for the latest datasheet, sample details, and a project quotation.
For general CO alarm safety information, visit the U.S. Consumer Product Safety Commission CO alarm guidance.